Preventing the ingress of moisture through the cable of submersible pressure transmitters and level probes?

If you want to measure the degree of a liquid easily and reliably, a lot of people can do this using hydrostatic pressure measurement, e.g. with a submersible pressure transmitter or perhaps a so called level probe. The characteristic submersed application implicates a maximum contact with the surrounding, mainly water-based medium, respectively to ?moisture?.
Exposure isn’t only limited to the wetted elements of the pressure sensor housing, but additionally to the complete immersed length of the cable. Furthermore, beyond your directly immersed level probe parts, the cable, and in particular the cable end, are often exposed to moisture due to splash water, rain and condensation. That is true not only during operation, but even more during installation and commissioning, or when maintenance or retrofitting is required. Irrespective of the prospective application, whether in water and wastewater treatment or in tank monitoring, moisture ingress in to the cable ends of the submersible pressure transmitter may appear early and irreversibly with insufficient protection measures, and, in virtually all cases, lead to premature failure of the instrument.
The ingress of moisture in to the cable outlet and from there on downwards into the electronics of the level probe should be actively eliminated by preventive actions by an individual. To gauge the level with highest accuracy, the varying ambient pressure above the liquid media, which is also ?resting? on the liquid, must be compensated against the hydrostatic pressure functioning on the pressure sensor (see article: hydrostatic level measurement).
Ventilation tube
Thus, it really is logical that there surely is a constant risk of a moisture-related failure because of moisture ingress (both via the ventilation tube and through the actual cable itself) if there are no adequate precautionary measures. To pay the ambient pressure ?resting? on the media, a ventilation tube runs from the sensor element within the particular level probe, through the cable and out from the level probe at the end of the cable. Due to capillary action within the ventialation tube useful for ambient pressure compensation, moisture can also be transported from the encompassing ambience right down to the sensor.
Thus not only air, but additionally moisture penetrates in to the tube, hence the sensor inside the probe and the electronics around it might be irreparably damaged. This may result in measurement errors and, in the worst case, even to failure of the particular level probe. To avoid any premature failure, the ingress of moisture into the ventilation tube should be completely prevented. Additional protection against moisture penetration through the ventilation tube is supplied by fitting an air-permeable, but water-impermeable filter element by the end of the vent tube.
bare wires
Never to be ignored can be the transport of the liquid through high-humidity loads along the only limitedly protected internals of the cable, e.g. across the wires, completely right down to the submersible pressure transmitter. As a leading manufacturer, WIKA uses appropriate structural design to avoid fluid transport, as far as possible, in to the electronics of the submersible pressure transmitter. Due to molecular diffusion and capillary effects, a guaranteed one-hundred percent protection over the full lifetime of the submersible pressure transmitter, however, is never achievable.
It is therefore recommended that the cable is definitely terminated in a waterproof junction box with the appropriate IP protection (e.g. IP65) which is matched to the installation location. If this cable junction box is subjected to weather and varying temperature conditions, it is also recommended to pay attention to a controlled pressure equalisation in order to prevent the formation of condensation or perspiration water and pumping effects. To handle this technical requirement, being an accessory to a submersible pressure transmitter, it is possible to order a connection box having an integrated air-permeable, water-impermeable membrane.
Ultimately, Turbo-charge can happen not only through the exposed end of the cable, but additionally through mechanical harm to the cable sheath or because of liquid diffusion due to improper chemical resistance of the cable material. In this article ?Selection criteria for the prevention of moisture-related failures of submersible pressure transmitters or level probes? this failure mode is described at length.
WIKA offers comprehensive solutions for the hydrostatic-pressure level measurement. For further assistance in selecting the submersible pressure transmitter most suitable for the application, please use our contact form.
Please find further information with this topic on our information platform ?Hydrostatic level measurement?g